ECOFER OIKONOMOU - Official Representative of FAIRLAND products
When the season starts, the Full-inverter HP runs at 100% capacity to heat up the pool in the first few days. After that, the Full-inverter HP runs at AVERAGE 50% capacity to maintain the desired pool temperature. Normally, the pool temperature drops 0.5~1.5℃ daily, 50% capacity of a Full-inverter HP is sufficient to heat the pool by 1.5~2.2℃ in 15 hours running with the right model selection. The AVERAGE COP 11.5 leads to half the running cost compared with an On/Off HP. Meanwhile, the AVERAGE sound pressure of a Full-inverter HP is 45.2 dB(A) at 1m, which is 10 times quieter than an On/Off HP and even can be negligible.
The new TurboSilence Inverter technology is an optimization of the Full-inverter technology, upgrading the entire control system and the corresponding components, and providing the possibility of an immediate increase in heating capacity by 20%, along with silent operation. A 20% increase in power translates practically into 20% extra heat for free. Turbosilence means ultimate energy savings, particularly quiet operation with half the energy consumption costs. The air is extracted with a patented system for unique airflow, which in combination with the double rotary compressor, minimizes vibration and leads to the quietest ventilation. Maintaining the pool temperature during the bathing season requires operation at 50% average power, which means a 10 times quieter swimming environment. The average COP value of 11.3 in 50% mode and the maximum COP value of up to 16 result in double the energy savings compared to a conventional pool heat pump.